Water Systems
Skip Navigation Links
Franklin AIM - Page 50
 
Table 50  Integral Horsepower Control Box Parts 60Hz
Motor Size Motor Rating HP

Control Box (1)
Model No.

Capacitors Overload (2) Part No. Relay (3) Part No. Contactor (2) Part No.
Part No. (2) Mfd. Volts Qty.
4" 1-1 1/2 Standard 282 3008 110 275 464 113 S 105-126 220 1 275 411 107 155 031 102  
155 328 102 R 10 370 1
282 300 8610 275 464 113 S 105-126 220 1 None
(See Note 4)
155 031 102  
155 328 101 R 15 370 1
4" 2 Standard 282 3018 110 275 464 113 S 105-126 220 1

275 411 107 S

275 411 113 M

155 031 102  
155 328 103 R 20 370 1
4" 2
Deluxe
282 3018 310 275 464 113 S 105-126 220 1

275 411 107 S

275 411 113 M

155 031 102 155 325 102 L
155 328 103 R 20 370 1
4" 3
Standard
282 3028 110 275 463 123 S 208-250 220 1

275 411 108 S

275 411 115 M

155 031 102  
155 327 109 R 45 370 1
4" 3
Deluxe
282 3028 310 275 463 123 S 208-250 220 1

275 411 108 S

275 411 115 M

155 031 102 155 325 102 L
155 327 109 R 45 370 1
4" & 6" 5
Standard
282 1138 110 275 468 119 S 270-324 330 1

275 411 102 S

275 406 102 M

155 031 601  
155 327 114 R 40 370 2
4" & 6" 5
Deluxe
282 1138 310 or
282 1139 310
275 468 119 S 270-324 330 1

275 411 102 S

275 406 102 M

155 031 601 155 326 101 L
155 327 114 R 40 370 2
6" 7 1/2
Standard
282 2019 210 275 468 119 S 270-324 330 1

275 411 102 S

275406 122 M

155 031 601  
275 468 118 S 216-259 330 1
155 327 109 R 45 370 1
6" 7 1/2
Deluxe
282 2019 310 275 468 119 S 270-324 330 1 275 411 102 S

275 406 121 M
155 031 601 155 326 102 L
275 468 118 S 216-259 330 1
155 327 109 R 45 370 1
6" 10
Standard
282 2029 210 275 468 119 S 270-324 330 1

275 406 103 S

 

155 409 101 M

155 031 601  
275 468 120 S 350-420 330 1
155 327 102 R 35 370 2
6" 10
Standard
282 2029 230 275 463 120 S 130-154 330 1

275 406 103 S

 

155 409 101 M

155 031 601  
275 468 118 S 216-259 330 1
275 468 119 S 270-324 330 1
155 327 102 R 35 370 2
6" 10
Deluxe
282 2029 310 275 468 119 S 270-324 330 1

275 406 103 S

155 409 101 M

155 031 601 155 326 102 L
275 468 120 S 350-420 330 1
155 327 102 R 35 370 2
6" 10
Deluxe
282 2029 330 275 463 120 S 130-154 330 1

275 406 103 S

 

155 409 101 M

155 031 601 155 326 102 L
275 468 118 S 216-259 330 1
275 468 119 S 270-324 330 1
155 327 102 R 35 370 2
6" 15
Deluxe
282 2039 310 275 468 120 S 350-420 330 2

275 406 103 S

155 409 102 M

155 031 601 155 429 101 L
155 327 109 R 45 370 3
6" 15
Deluxe
282 2039 330 275 463 122 S 161-193 330 3

275 406 103 S

155 409 102 M

155 031 601 155 429 101 L
155 327 109 R 45 370 3
6" 15
X-Large
282 2039 621 275 468 120 S 350-420 330 2

275 406 103 S

155 409 102 M

155 031 601

2 Required
155 429 101 L
155 327 109 R 45 370 3
 

FOOTNOTES:

  1. Lightning arrestors 150 814 902 are suitable for all control boxes.

  2. S = Start, M = Main, L = Line, R = Run
    Deluxe = Control box with line contactor.

  3. For 208 V systems or where line voltage is between 200 V and 210 V, a low voltage relay is required. On 3HP and smaller control boxes use relay part 155 031 103 in place of 155 031 102 and use the next larger cable size than specified in 230 V table. On 5 hp and larger use relay 155 031 602 in place of 155 031 601 and next larger wire. Boost transformers per page 15 are an alternative to special relays and cable.

  4. Control box model 282 300 8610 is designed for use with motors having internal overload protectors. If used with a 1.5 hp motor manufactured prior to date code 06H18, Overload/Capacitor Kit 305 388 901 is required.