Ohmmeter Tests
|
QD,
Solid State Control Box (Power Off) |
|
A. START CAPACITOR AND RUN CAPACITOR IF APPLICABLE
(CRC)
- Meter Setting: R x 1,000.
- Connections: Capacitor terminals.
- Correct meter reading: Pointer
should swing toward zero, then back to infinity.
B. Q.D. (BLUE) RELAY
- Step 1. Triac Test
- Meter setting: R x 1,000.
- Connections: Cap and B terminal.
- Correct meter reading: Infinity
for all models.
- Step 2. Coil Test
- Meter Setting: R x 1.
- Connections: L1 and B.
- Correct meter reading: Zero ohms
for all models.
- C. POTENTIAL (VOLTAGE) RELAY
- Step 1. Coil Test
- Meter setting: R x 1,000.
- Connections: #2 & #5.
- Correct meter readings:
- For 115 Volt Boxes
.7-1.8 (700 to 1,800 ohms).
- For 230 Volt Boxes 4.5-7.0
(4,500 to 7,000 ohms).
- Step 2. Contact Test
- Meter setting: R x 1.
- Connections: #1 & #2.
- Correct meter reading: Zero for
all models.
D. SOLID STATE SWITCH
- Step 1. Triac Test
- Meter Setting: R x 1,000.
- Connections: R (Start) terminal
and orange lead on start switch.
- Correct meter reading: Infinity
for all models.
-
- Step 2. Coil Test
- Meter Setting: R x 1.
- Connections: Y (Common) and L2.
- Correct meter reading: Zero ohms
for all models.
|
Ohmmeter Tests |
Integral
Horsepower Control Box (Power Off) |
A. OVERLOADS (Push Reset Buttons to make sure contacts are closed.)
- Meter Setting: R x 1.
- Connections: Overload terminals.
- Correct meter reading:
Less than 0.5 ohms.
B. CAPACITOR (Disconnect leads
from one side of each capacitor before checking.)
- Meter setting: R x 1,000.
- Connections: Capacitor
terminals.
- Correct meter reading:
Pointer should swing toward zero, then drift back to infinity,
except for capacitors with resistors which will drift
back to 15,000 ohms.
C. RELAY COIL (Disconnect lead from Terminal #5)
- Meter setting: R x 1,000.
- Connections: #2 & #5.
- Correct meter readings:
4.5-7.0 (4,500 to 7,000 ohms) for all models.
D. RELAY CONTACT (Disconnect lead
from Terminal #1)
- Meter Setting: R x 1.
- Connections: #1 & #2.
- Correct meter reading:
Zero ohms for all models.
E. CONTACTOR COIL (Disconnect
lead from one side of coil)
- Meter Setting: R x 100.
- Connections: Coil terminals.
- Correct meter reading:
180 to 1,400 ohms.
F. CONTACTOR CONTACTS
- Meter Setting: R x 1.
- Connections: L1 & T1 or
L2 & T2.
- Manually close contacts.
- Correct meter reading:
Zero ohms.
|
|
CAUTION: The tests in this manual for components such as capacitors,
relays, and QD switches should be regarded as indicative and
not as conclusive. For example, a capacitor may test good (not
open, not shorted) but may have lost some of its capacitance
and may no longer be able to perform its function.
|
|
| |
| |