Franklin Electric     Franklin Electric  
  WS Home     Pumps     Motors, Controls & Drives     Facts / News     Service     AIM Manual     Training     Franklin AID  
  Contact Us     Search  
 

  Location:   Water Systems Home > 4" Motors > 4" Polluton Recovery

  Dimensions are available on page 2
4" POLLUTION RECOVERY SUBMERSIBLE MOTORS

    Single-phase
1/3 through 1 1/2 - 2-wire
1/3 through 2 Hp - 3-wire
115, 230 volt - 60 Hz; 220 volt - 50 Hz:

Three-phase
1/2 through 2 Hp - 3-wire
200, 230, 380, 460, 575 volt - 60 Hz; 220, 380 volt - 50 Hz

APPLICATION DATA
These motors are built for dependable operation in 4" diameter or larger environmental wells. Temperature and time rating continuous in 86°F (30°C) water.

Rotation: Single-phase are CCW facing shaft end. Three-phase are electrically reversible.

These motors have the same electrical characteristics as the standard 2-wire, 3-wire, and three-phase Super Stainless motors.

For further information, refer to Franklin Electric's "Application Installation Maintenance Manual (AIM)" for submersible motors.

 
BASIC FEATURES
  • Corrosion-Resistant All Stainless Steel Exterior Construction
  • Stainless Steel Splined Shaft
  • Hermetically-Sealed Windings
  • Anti-Track Self Healing Resin System
  • Water Lubrication
  • Filter Check Valve
  • Kingsbury-Type Thrust Bearing
  • Pressure Equalizing Diaphragm
  • Built-In Lightning Arrestors (all single-phase; 200 and 230 volt three-phase)
  • Removable Water-Bloc™ Lead Connector (sold separately)
  • U.L. 778 Recognized
  • CSA C22.2 #108 Certified
  • NEMA Mounting Dimensions
SPECIAL FEATURES
  • Pollution Recovery motors are equipped for use in monitoring and recovery wells in which hydrocarbons and other chemicals may be present.
  • Special Viton® rubber parts and other construction materials used in this motor are defined on the reverse side.
  • Special Pollution Recovery grounded lead assemblies are sold separately. See reverse side for available lengths.
  • No flow inducer sleeve required in water up to 86°F (30°C).
  • Two-wire motors are split phase designs with integral starting components and do not require a control box. They feature FRANKLIN'S patented 2-wire BIAC starting switch which provides automatic torque reversal to aid starting in adverse environments and prevents extreme fast cycling (e.g. due to water logged tank).
  • Three-wire motors use FRANKLIN'S exclusive 3-wire QD (QuickDisconnect) control box with the patented QD Relay. This relay provides the ultimate in operational life.
  • #316 Stainless Steel: special construction option for acid, low pH and seawater application

- Viton is a registered trademark of DuPont Dow Elastomers.

 
  WARNINGS: Serious or fatal shock may result from failure to connect all metal plumbing, and the motor, if outside a drilled well, to the power supply grounding terminal with no wire smaller than motor cable wires. Do not use motor in swimming areas.
 
1.99 Dimensions are available on page 2
 
 
  Home     Corporate     Water Systems     EMPD - Fractional HP Motors     Fueling Systems     International  
  TOP  

Copyright 1998-2004.  Please review our Terms of Use before accessing this site.
Franklin Electric Co., Inc.        400 E. Spring St.,  Bluffton,  IN,  46714,  U.S.A.