4" SAND FIGHTER™ SUBMERSIBLE MOTORS
 


CONTROL BOXES
Franklin's single-phase submersible Control Boxes are suitable for outdoor mounting with operation over temperature ranges of +14°F to +122°F.
Start and run winding overloads protect the motor from failure due to abnormal operating conditions.
Available in 3 and 5 HP ratings, the DELUXE Control Box incorporates a magnetic line contactor to eliminate the need for auxiliary contactors and heavy duty pressure switches.
A heavy duty terminal strip with box type lugs makes it easy to install up to #2 AWG wire.
Ground lugs provide a means of grounding the motor and Control Box to the power supply ground in compliance with NEC and other National and local codes.

   
Single-phase     2 through 5 horsepower
230 Volts - 60 Hertz
     
Three-phase   3 through 10 horsepower
200, 230, 380, 575 volts - 60 Hertz
460/380 volts - 60/50 Hertz

APPLICATION DATA
These motors are built for superior dependability in 4" diameter or larger sandy water wells. Temperature and time rating continuous in 86°F (30°C) water at 1/4 ft. per second flow past motor. Rotation: single-phase - CCW; three-phase - electrically reversible.

For further information, refer to Franklin Electric's "Submersible Motors: Application, Installation, Maintenance Manual."

SAND FIGHTER™ MOTOR FEATURES
Exclusive Sand Fighter™ Sealing System
Warranted Against Sand Entry Failure

BASIC FEATURES
Corrosion-Resistant Construction
Stainless Steel Splined Shaft
Hermetically-Sealed Windings
Anti-Track Self-Healing Resin System
Water Lubricated Bearings
Filter Check Valve
Kingsbury-type Thrust Bearing Rated for 1500 lbs. Downthrust
Pressure Equalizing Diaphragm
Built-in Lightning Arrestors (single-phase)
Removable "Water-Bloc™ Lead System"
NEMA Pump Mounting Dimensions
UL 778 Recognized
CSA C22.2 #108 Certified

WARNING: Serious or fatal electrical shock or fire hazard may result from failure to follow the instructions for proper installation and use which accompany this equipment. Do not use motor in swimming areas.

 
M1460 ? 3.04 Dimensions are available on page 2
"Left click" to VIEW pdf. To SAVE pdf "Right Click" & choose
 
 
 
  Home     Corporate     Water Systems     Fueling Systems     International  
  TOP  

Copyright 1998-2007.  Please review our Terms of Use before accessing this site.
Franklin Electric Co., Inc.        400 E. Spring St.,  Bluffton,  IN,  46714,  U.S.A.
Contact Us              Tel: 260.824.2900           Fax: 260.824.2909