| (1) |
Main winding - yellow to black
Start winding - yellow to red |
| |
|
| (2) |
Y = Yellow lead - line amps
B = Black lead - main winding amps
R = Red lead - start or auxiliary winding amps |
| |
|
| (3) |
Control Boxes date coded 02C
and older have 35 MFD run capacitors and the current
values will be |
| Y14.0 @ FL and |
Y17.0 @ SF Load. |
| B12.2 |
B14.5 |
| R4.7 |
R4.5 |
|
|
|
| (4) |
Control Boxes date coded 01M
and older have 60 MFD run capacitors and the current
values on a 4" motor will be |
| Y23.0 @ FL - |
Y27.5 @ SF Load. |
| B19.1 |
B23.2 |
| R8.0 |
R7.8 |
|
| |
|
| (5) |
Control Boxes date coded 01M
and older have 60 MFD run capacitors and the current
values on a 6" motor will be |
| Y23.0 @ FL - |
Y27.5 @ SF Load. |
| B18.2 |
B23.2 |
| R8.0 |
R7.8 |
|
|